System Center Data Access Service won’t start after SCOM 2012 Upgrade

After upgrading the RMS in a SCOM 2007 r2 upgrade scenario to SCOM 2012 there is an issue starting the System Center Data Access Service. It won’t start during the default timeout. (event id 7009)

to fix this, apply the following registery key:

quoted from KB2730040 http://support.microsoft.com/en-us/kb/2730040

To increase the default service time-out, follow these steps:

1.Click Start, click Run, type regedit in the Open box, and then click OK.
2.Locate and then select the following registry subkey:

HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control

3.Right-click Control, point to New, and then click DWORD.
4.In the New Value box, type ServicesPipeTimeout, and then press Enter.
5.Right-click ServicesPipeTimeout, and then click Modify.
6.Click Decimal, type the number of milliseconds that you want to wait until the service times out, and then click OK.

For example, to wait 60 seconds before the service times out, type 60000.